The following RAID controller configuration procedure applies to Forge appliances based on Dell PowerEdge R610/R620 hardware.
On first boot, you use the PERC 6/I Configuration utility to configure the RAID controller:
- At the RAID Controller boot prompt, approximately 10 seconds into the boot sequence, press Ctrl+R.
- Configure the PERC RAID controller to have two logical disks consisting of two physical disks in RAID 1:
- Delete any existing disk groups:
- Select a disk group and press F2.
- Select Delete Disk Group.
- Repeat Step 2.a.a and Step 2.a.b for all existing disk groups.
- Create a new disk group for the Forge system:
- Select the controller and press F2.
- Select Create New VD, press Enter on RAID Level, then select RAID 1.
- Select both physical disks (disk sizes might vary).
- Under Basic Settings, fill in the following fields:
- VD Size: Use 307200 as the value.
- VD Name: Use ForgeSystem as the value.
- Create a new disk group for the failover VMs:
- Select the controller, select Disk Group 0, then press F2.
- Select Add New VD, then select RAID 1.
- Select both physical disks (disk sizes might vary).
- Allocate all remaining disk space for the VD size.
- Type FailoverVMs as the VD Name value, select OK, then press Enter.
- Choose to fast-initialize both VD disks:
- Select a virtual disk and press F2.
- Select Initialization > Fast Init.
- Verify that the final RAID configuration looks like the following:
- Press Ctrl+Alt+Del if prompted. The server reboots.